What it is
A complete 0.8 L thermoelectric water cooling module for OEM water and beverage appliances.
LL-08B brings the main cooling components into one 0.8 L module: dual thermoelectric (Peltier/TEC) coolers, cold-pipe conduction, heat-pipe heat rejection, forced airflow and dual NTC sensing. Semiconductor cooling is another valid description of this technology; superconducting cooling is not.

A complete 0.8 L thermoelectric water cooling module for OEM water and beverage appliances.
Compressor-free appliances that can provide the specified DC supply, cabinet airflow, water connections and mounting space.
Insulated tank, dual TECs, cold-side conduction, heat-pipe heat rejection, fan and dual NTC sensing.
Inlet-water temperature, target cold-water temperature, draw cycle, DC configuration, airflow and cabinet integration.
The main image shows the full assembled module. Additional views explain its construction, interface positions and installation envelope.
01 · Complete product
In / out φ11AirflowDrain φ7.5
165 × 115 × 308 mm4 × φ3.3

Published hourly output is measured with 25°C ambient temperature, 25°C inlet water, rated electrical input and unobstructed fan inlet and outlet. The initial draw is excluded.
Dual TECs move heat away from the insulated tank. Cold-pipe conduction distributes cooling at the water side, while the heat-pipe condenser and fan reject heat to the appliance airflow. Dual NTC sensors support temperature monitoring.
In / out φ11AirflowDrain φ7.5| Model | LL-08B |
|---|---|
| Product type | Complete thermoelectric water cooling module |
| Tank capacity | 0.8 L |
| Cooling devices | Dual 12706 TEC |
| Rated input | 130±10 W |
| Supply configuration | DC 12 V or 24 V according to TEC series or parallel configuration |
| Noise | <35 dB |
| Dimensions | 165×115×308 mm |
| Net weight | 1.45 kg |
| Sensors | Two B3950 / 10K NTC sensors |
| Mounting holes | 4×φ3.3 |
| Published cold-water output | >2 L/h at ≤10°C; >3.2 L/h at ≤15°C |
| Output conditions | 25°C ambient and inlet water, rated input, unobstructed airflow, first draw excluded |
Use the approved public information on this page for initial screening. Before fixing the appliance design, request the current product drawing and confirm that its revision matches the proposed sample.
Document detail depends on the project stage. Confidential CAD, BOM, supplier information and unverified certificates are not published on the website.
Request current documentsConnect LL-08B performance to cabinet airflow, inlet water and the draw pattern.
Read guide →Separate water energy, passive heat leak, electrical input and cabinet heat rejection before comparing recovery.
Read guide →Compare demand profile, heat rejection, appliance space and validation needs before choosing the cooling architecture.
Read guide →Start with the system boundary, operating conditions and appliance interfaces.
Read guide →It includes the insulated 0.8 L tank, dual TECs, cold-pipe conduction, heat-pipe condenser, fan and dual NTC sensors. The appliance provides the correct power supply, water connections, mounting and cabinet airflow.
Yes. Thermoelectric is the preferred technical term; Peltier, TEC and semiconductor cooling are valid descriptions here. Superconducting cooling describes a different physical concept and is not correct for LL-08B.
The specification states this output under 25°C ambient and inlet-water temperature, rated input and unobstructed airflow, with the first draw excluded.
No. The fan inlet and outlet must remain unobstructed. Restricted airflow can reduce cooling capacity.
Share the installation space, inlet-water temperature, target cold-water temperature, draw pattern, power configuration and airflow arrangement.