MICROCRYSTALLINE HEATING ELEMENT

LL-JRB-004B

High-Output Ceramic Heating Element

The higher-power option in the shared 004 housing for appliances whose supply, water path and protection logic support 3000 W.

LL-JRB-004B is the heating section of an OEM water appliance. It combines the heating path, water housing, inlet/outlet sensing and dual temperature protection. The appliance supplies the pump, valves, main controller and system-level safety logic.

LL-JRB-004B High-Output Ceramic Heating Element
3000 Wrated power +5% / −10%
50 × 36 × 155 mmproduct envelope
>10,000 hrated service life
≥97%specified thermal efficiency
PRODUCT DECISION SUMMARY

When should an OEM shortlist LL-JRB-004B?

What it is

A 3000 W microcrystalline ceramic heating element. It is not a complete instant-heating module.

Why this model

The higher-power option in the shared 004 housing for appliances whose supply, water path and protection logic support 3000 W.

LELING supplies

Heating path and water housing, inlet/outlet sensing points, 125°C auto-reset protection and 145°C manual-reset protection.

OEM must confirm

Pump and flow control, valves, 220 V power architecture, main controller, grounding, dry-heating protection and whole-appliance compliance.

See the complete product before the engineering details

The sequence covers the assembled element, alternate view, interfaces, installation envelope, internal structure and protection design.

Why this model enters a shortlist

3000 Wrated heating power
2300 mL/minroom-temperature water flow
>10,000 hrated service life
0 MParated pressure

The listed flow is a room-temperature water-path value.

It is not a guaranteed hot-water output. Final outlet temperature and hot-water flow depend on inlet temperature, target temperature, pump curve, voltage, control logic and duty cycle, and must be validated in the target appliance.

LL-JRB-004 FAMILY

Choose between the two shared-housing 004 variants

Both models use the same 50 × 36 × 155 mm housing and require vertical installation with the outlet upward. Select by rated power, water-path target, protection setting and the appliance electrical design.

Related 004 model

LL-JRB-004A

Rated power
2200 W
Room-temperature flow
2000 mL/min
Temperature protection
135°C auto reset · 145°C manual reset
Compare LL-JRB-004A →
Current model

LL-JRB-004B

Rated power
3000 W
Room-temperature flow
2300 mL/min
Temperature protection
125°C auto reset · 145°C manual reset
You are viewing this model

The flow values above are room-temperature water-path specifications, not guaranteed hot-water output.

The product boundary is clear before integration

LELING supplies the heating element and its component-level protection. The OEM appliance completes water delivery, power control and whole-system safety.

01

Included in the element

  • Heating tube and water housing
  • Inlet and outlet NTC sensing points
  • Auto-reset protector 125°C
  • Manual-reset protector 145°C
02

Provided by the appliance

  • Pump and flow control
  • Inlet and outlet valves
  • Main controller and user interface
  • System safety, grounding and compliance

Interfaces and required installation direction

Install vertically with the water outlet facing upward. Confirm water connectors, NTC terminals, power terminals, grounding, cable routing and the dry-heating protection sequence in the appliance drawing review.

LL-JRB-004B Interfaces and required installation directionWater inletOutlet upward220 V AC · NTC
50 × 36 × 155 mmVertical installation required

Published engineering specification

ModelLL-JRB-004B
Product typeHeating element, not a complete heating module
Rated supply220 V AC ±10%, 50 Hz
Rated power3000 W, +5% / −10%
Dimensions50 × 36 × 155 mm
Rated pressure0 MPa
Thermal efficiency≥97%
Room-temperature water flow2300 mL/min
Rated service life>10,000 h
Heating path / housingMicrocrystalline ceramic tube · nylon housing
InstallationVertical, outlet upward
NTC sensorsInlet + outlet, R25=100K±1%, B25/50=3950±1%
Dielectric strength2000 V AC / 60 s, leakage ≤5 mA
Leakage current≤0.5 mA at 234 V / 10 s
Ground resistance<0.1 Ω at 25 A / 10 s
Leak test18 kPa / 5 s, leakage ≤15 mL
Temperature protection125°C auto reset + 145°C manual reset

Integration safety note

Dry heating is prohibited. Water flow and protection sequencing must be established by the appliance controller.

ENGINEERING DOCUMENTS

Ask for the current LL-JRB-004B drawing package

Use the approved public information on this page for initial screening. Before fixing the appliance design, request the current product drawing and confirm that its revision matches the proposed sample.

01

Available on this page

  • Published specification and stated conditions
  • Product, installation and interface visuals
  • Supply boundary and appliance-side responsibilities
02

Confirm during project review

  • Current drawing and document revision for the selected model
  • Water, electrical, sensing, mounting and installation interfaces
  • Open appliance conditions and the next validation items

Document detail depends on the project stage. Confidential CAD, BOM, supplier information and unverified certificates are not published on the website.

Request current documents

LL-JRB-004B integration questions

Is this a complete instant-heating module?

No. It is a heating element. The appliance must provide the pump, valves, main controller, power architecture and system-level protection.

Can the room-temperature flow be used as hot-water output?

No. It describes the water-path test at room temperature. Hot-water output must be calculated and validated for the required temperature rise and appliance cycle.

How should it be installed?

Vertically, with the outlet facing upward. The final drawing review must also confirm terminals, grounding, cable routing and available space.

Can it run without water?

No. Dry heating is prohibited. The appliance must establish water flow and protection logic before energizing the heater.

Check LL-JRB-004B against your water path and duty cycle.

Share inlet temperature, target outlet temperature, required flow, supply, available vertical space, control architecture and annual quantity.

Discuss LL-JRB-004B